Add to Cart
Portable LED Finger Pulse Oximeter New Design Export Only Blood Oxygen Monitor
Fingertip Pulse Oximeter Operation:
1) SpO2 value display
2) Pulse rate value display, bar graph display
3) Pulse waveform display
4) PI value display
5) The display mode can be changed
6) Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage
7) Pulse sound indication and over limit indication
Fingertip Pulse Oximeter Parameters
Product Name | LED Display Private Model Pulse Oximeter |
Measurement Range | SpO2: 35%-99% |
Pulse Rate(PR): 30~240BPM | |
Measurement Time | ≤20S |
Resolution | Spo2: ±1% |
Pulse Rate(PR): ±1BPM | |
Accuracy | ±1%(90%-99%) ; ±2% (70%-89%); unspecified(≤70%) for Spo2 |
Low Perfusion | ≤0.4% |
Power | Two of 1.5(AAA Size) alkaline batteries |
Power Consumption | <30mA |
Automatic Power-off | The product will automatically power off when no signals for 8s. |
Operation Environment | Operation temperature: 5℃~40℃ |
Humidity: 30%~90% | |
Air pressure: 59KPa~107.4KPa | |
Dimension | 58*32*22mm |
Net Weight | 27.5g (Batteries Not Included) |
Package | 1 Unit/Box, 200 Boxes/Ctn |
Carton Size | 40*28*31cm |
G.W./Carton | 8.1kg |
Certificates | CE |
Warranty | 6 months |
Fingertip Pulse Oximeter Features
Display Mode:0.96" LED display
Screen Resolution:128*64
SpO2 Measuring Range:0%~100%, (the resolution is 1%), accuracy:70%~100%:±2% ,Below 70% unspecified.
PR Measuring Range:30 bpm~250 bpm, (the resolution is 1 bpm), accuracy:±2 bpm or ±2% (select larger)
PI Measuring Range: 0 %~ 20%, accuracy:When the PI measure range is 1%~20%,the permission of absolute error is ±1%. When the PI measure range is 0%~0.9%,the permission of absolute error is ±0.2%
Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%
Power Consumption:less than 80 mA
Voltage: DC 2.6 V - 3.6 V
Power Supply:1.5 V (AAA size) alkaline batteries × 2
Safety Type:Interior Battery,BF Type
About Us
We're generally specialized in 5 fields:
1. Diabetes Care: Lancet, Lancing Device, Insulin Pen Needle, Insulin Syringe, Safety Pen Needle, Blood Glucose Meter and Test Strip etc.;
2. Household & Hospital Medical Equipment: Thermometer, Oximeter, Nebulizer, Blood Pressure Monitor and Oxygen Concentrator etc.;
3. Wound Dressing: Wound Dressing Patch, Fixation Retention Roll, Medical Tape, Various Bandage and Pain Relief Patch etc;
4. Surgical Device: Surgical Blade, Disposable Scalpel and Surgical Suture etc;
5: PPE: Masks, Protective Coverall, Surgical Gown, Safety Goggle, Medical Examination Glove and Surgical Glove etc.